RM122, RM123 Using the refrigerator
19
8.4 Connecting to a gas source
A
It must be possible to isolate the refrigerator separately by means of a shut-off device
in the gas connection. The shut-off device must be easily accessible.
➤ Connect the refrigerator to a gas source as shown in fig. b, page 7.
Use a cutting ring coupling according to EN 1949, firm and off circuit.
A rubber hose connection is not permitted.
➤ Ensure that gas connections are checked by a qualified gas engineer.
9 Using the refrigerator
!
A
NOTICE!
• The device must only be connected by a qualified electrician in
accordance with applicable regulations and standards to the gas
supply.
• Only use cylinders of propane or butane gas (not natural gas) with an
approved regulator. Compare the pressure specifications on the
data plate with the pressure indication on the propane or butane gas
bottle.
• The device must only be operated at the pressure indicated on the
data plate.
• Please note the pressures which are permitted in your country. Use a
DIN-DVGW-approved pressure regulator with a fixed setting in
accordance with DIN EN 12864.
• Note the norms EN 732 and EN 1949.
CAUTION! Health hazard!
If you wish to cool medicines, please check if the cooling capacity of the
appliance is suitable for the medicine in question.
NOTICE!
• Only put items in the refrigerator which can be kept at the selected
temperature.
• Food may only be stored in its original packaging or in suitable con-
tainers.
rm122_rm123-EN.book Seite 19 Dienstag, 7. Februar 2017 9:00 09