31
The Thermocouple is a component that extends over the
burner assembly so its tip is in the path of the ame. Dur-
ing normal gas operation, the thermocouple should pro-
duce 25 to 35 millivolts DC when connected to the lower
circuit board. Any reading below 20 millivolts DC could
cause erratic gas operation. NOTE: A reading of 20 or
less could be caused by low gas pressure, carbon build
up or improper thermocouple location. The thermocou-
ple should be centered over the burner and extend over
3 slots. The control board reads negative millivolts DC
from the thermocouple and the positive lead goes to the
ground terminal on the control board. The lower control
has built-in delay when the unit is rst turned on. If the
lower control reads millivolts in excess of 6 MVDC the
control will go into a 30 second gas delay before attempt-
ing to light on gas. To test the thermocouple set the meter
to DC millivolts. Put the black lead from the meter to ter-
minal J4 and the red lead from the meter to J10 or ground
(other lead from thermocouple). Start the unit on gas and
measure the DC millivolts produced by the thermocouple.
The thermocouple should produce 22 to 36 millivolts DC
within 45 seconds. If the millivolts are 20 or below erratic
operation will occur. Anything below 10 to 13 the control
board will not keep the gas valve energized and turn on
the check light after the third trial-for-ignition. Approx 6 to
7 minutes.
8.2 Orice
The Dometic orice is a brass alloy with a man-made ruby
pressed in the center that has been laser-beam drilled in
a spiral pattern. The orice is cleaned by using an alcohol
based solvent. Soak the orice for approximately 1 hour
and allow to air dry. Don’t insert anything in the center of
the orice because it will harm the man-made ruby. Do
not use an air nozzle to blow thru the orice as the ruby
could be moved. Never over or under size the orice on a
Dometic refrigerator. The cooling unit is designed to work
with a predetermined amount of heat and modifying the
orice size will decrease cooling. If there is a lack of cool-
ing on gas operation, verify the orice is the proper size
per the chart.
MODEL JET SIZE
RM1350 #76
Always check the parts list with the model and product
number to assure the right jet size.
DO NOT use a wire or pin when cleaning the burner
jet as damage can occur to the precision opening.
This can cause damage to the refrigerator or create
a re hazard.
8.3 Thermocouple
5. Remove protection cover from burner and open the
manual gas shutoff valve. Do not change any button posi-
tions on the control panel. Apply a non-corrosive commer-
cial bubble solution to the burner jet orice.
6. No bubbles should appear at the opening of the burner
jet orice. The presence of bubbles indicates a defective
gas safety shutoff, and service is required.
7. If no bubbles were present at the burner jet orice, it
should be rinsed with fresh water. Be careful not to dam-
age the burner jet orice. Replace cover and press the
main power ON/OFF button OFF and back ON. Normal
operation of the burner should return. Allow the burner to
operate for a minimum of ve minutes.
AUTO mode lamp is lit and LP mode lamp is ashing.
Indicates temporary gas operation lockout.

Other manuals for Dometic RM1350