Troubleshooting RML10.4, RML10.4S, RML10.4T
34
7.1 Fault messages and signal tones
All faults are indicated by a warning symbol, a fault ID and a beep. The beeping lasts
for 2 minutes and is repeated every 30 minutes until the error has been rectified.
If multiple faults occur, the display shows the most recent fault. The underlying faults
are displayed after the last fault has been confirmed.
RML10.4T: Faults are indicated by a fault code with a warning symbol ( ) in the
middle of the TFT display.
RML10.4 and RML10.4S: In the event of a fault, the LED warning symbol (
) in the
display lights up continuously and the LEDs flash according to the fault.
The refrigerator is not
cooling adequately.
The ventilation around the cool-
ing unit is not sufficient.
Check that the ventilation grille is not
obstructed.
The evaporator is iced up. Check whether the refrigerator door
closes properly. Make sure that the
refrigerator seal fits correctly and is not
damaged. Defrost the refrigerator.
The temperature is set too high. Set a lower temperature.
The ambient temperature is too
high.
Remove the ventilation grille for a
while so that warm air can escape
quicker.
Too much food was placed in the
refrigerator at the same time.
Remove some of the food.
Too much warm food was placed
in the refrigerator at the same
time.
Remove the warm food and leave it to
cool down before putting it in again.
The refrigerator has not been
operating for very long.
Check the temperature again after four
or five hours.
Fault Possible cause Suggested remedy
RML10_OPM_WEST.book Seite 34 Mittwoch, 8. April 2020 2:18 14