RML10.4, RML10.4S, RML10.4T Troubleshooting
35
WARNING type fault messages
All faults of the WARNING type are reset automatically once the fault has been
rectified.
ERROR type fault messages
All faults of the ERROR type must be reset manually:
➤ RML10.4T: Press the control knob for 2 seconds.
➤ RML10.4 and RML10.4S: Press for 2 seconds.
✓ A beep sounds.
✓ The error has been reset.
RML10.4T
RML10.4,
RML 10.4S
Fault Solution
W01
Defective temperature sen-
sor in the refrigerator com-
partment
Contact an authorized customer
service point.
W05
AC power not connected or
AC voltage <190 V
Connect the refrigerator to AC
power or select a different energy
type, e.g. gas or DC power.
W06
DC power not connected Connect the refrigerator to DC
power or select a different energy
type, e.g. gas or AC power.
W11
DC overvoltage (>16 V). Reduce the DC supply voltage.
Tank stop mode: Gas opera-
tion is blocked for
15 minutes.
Wait 15 minutes or switch to another
operating mode.
W10
+ beep
Beep
The door has been open for
more than 2 minutes.
Close the door.