EPT052026 Issue 1 February 2019 (29)
Set counter ^1C01CS*x*y*z*
a*b*c*d*e\0
*x: Counter number. Range =
0-5. This is the name of the
counter that will be stored on
the printer.
*y=0: Count upwards.
*y=1: Count downwards.
*z=0: Do not fill zeros.
*z=1: Fill zeros.
*a: Counter steps. Range =
000-250 (mandatory 3
characters).
*b: Counter start value.
Range = 0000000001-
2000000000 (mandatory 10
characters).
*c: Current counter value.
Range = 0000000001-
2000000000 (mandatory 10
characters).
*d: Counter reset value.
Range = 0000000001-
2000000000 (mandatory 10
characters).
*e: Current repeat value.
Range = 0000000000-
0010000000 (mandatory 10
characters).
1C01CS0010010000000001000
00000010000000999\0
=
Counter number: 0
Count direction: Upwards
Fill zeros: Enabled
Counter steps: 1
Start value: 1
Current value: 1
Reset value: 999
Table 2: PLC to Printer
Operation Command Parameter Examples