Control Process Alerts
No. Alert Text Alert Level Description
5062 Trigger output pulse overlap Alarm
(Red Alert)
Trigger output pulses are overlapping.
Remedial action: Check the trigger
signal output configuration. Decrease
the pulse length of the trigger output in
the print trigger menu.
5100 No PD, Print Group n Alarm
(Red Alert)
No "Product Detect" detected during the
specified distance.
Remedial action: Check the "Distance to
check PD signal (mm)" setting in the
print trigger menu.
5101 Multiple PD, Print Group n Alarm
(Red Alert)
A "Product Detect" signal has been
received during printing.
Remedial action: Check the print trigger
setup. Check the length of printed label.
5102 Second PD while no
encoder, n
Alarm
(Red Alert)
A "Product Detect" signal has been
received when no encoder movement
has been detected.
Remedial action: Check the print trigger
setup.
5130 Auto-Swap Print Head n not
ready
Alarm
(Red Alert)
Auto-Swap cannot be disabled.
Remedial action: Turn o the "Inhibit
Auto-Swap" input signal.
Or check the status of the other print
head in the auto-swap pair.
5207 Print head n power error Alarm
(Red Alert)
A print head error has been detected.
Remedial action: Shut down the
controller. Remove the print head and
restart the controller.
5208 Print head n not supported Alarm
(Red Alert)
The connected print head is not
supported.
Remedial action: Shut down the
controller. Remove the print head and
restart the controller.
OPERATION