3.3. FACTORY SETTINGS
1. Disconnect the device from power supply.
2. Press and hold the «#» key.
3. Connect the device to power supply.
4. Having heard two signals release the «#» key, all settings have changed to factory settings.
IMPORTANT! Upon factory reset all information on users remains in the receiver memory.
4. DOOR PROGRAMMING
The keypad allows you to program the following door options:
1. Automatic door closing time (see p. 2 table 7).
2. «Door is opened for too long» (DOTL) warning (see p. 3 table 7). If an additional magnetic contact is used or a magnetic
lock contact is built in, when the door opens normally but does not close after 1 minute, an internal signal is automatically
given to remind people to close the door. The alarm goes on for a minute, then turns off automatically.
3. «Door opened by force» warning (see p. 4 table 7). If an additional magnetic contact is used or a magnetic lock contact is
built in, an internal signal and an alarm will be given if the door is opened by force or if the door is opened after 20 seconds.
Alarm time is adjustable from 0 to 3 minutes.
In case 10 invalid cards are applied or 10 incorrect PINs are entered within 10 minutes the keypad is locked (for 10 minutes)
or alarm sounds (for 10 minutes) depending on the options selected during setup.
The user should enter the programming mode to perform operations with the controller (see p. 1 table 7).
# Description Commands
8 Delete all users
To delete all users enter the programming mode and press
2 0000 #
9
Door opening:
3 0 mode (with a PIN)
3 1 mode (with a card and a PIN)
3 2 mode (with a card or a PIN)
Enter the PIN then press #
Apply the card then enter the PIN and press #
Apply the card
10 Setting of the door relay delay time
Master code # 4 0–99 #
0–99 — delay time in seconds
DOOR PROGRAMMING
Table 6 continued
# Description Commands
1
Entering the programming mode
999999 – preset factory master code
Master code #
The indicator will blink green and light up red. If the code has been entered
incorrectly then triple audible signal will be heard
2 Setting of the door relay delay time
Master code # 4 0–99 #
0–99 — delay time in seconds
3
Open door detection function
disabled (factory settings)
6 0 #
enabled 6 1 #
4
Door opened by force.
Time of alarm signalling – 1 minute (factory setting)
5 0~3 #
5
Keypad locking and alarm signal setting
disabled (factory settings)
7 0 #
keypad is locked 7 1 #
alarm signal is generated 7 2 #
6
Alarm reset
door opened by force
Apply a valid card / Enter Master code #
door opened too long
Close the door / Apply a valid card / Enter Master code #
Table 7. Door programming
14