OPEN Photo Sensor
Side View
UL sensor mounted
just below actuator
arm cable.
5” or less
Gate Closed
CLOSE Photo Sensor
Side End View
Entrapment Protection Locations
Closed Gate
21”
(53 cm)
Typical
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of photo sensors-Type B1 and/or
reversing edges-Type B2 entrapment protection required by UL 325 standards. Entrapment Protection must be provided for the gate system
where the risk of entrapment or obstruction exists. The operator will NOT run without one or more monitored type B1 or B2 external
entrapment protection devices installed in each entrapment area. Install these devices where the risk of entrapment or a safety hazard
exists. Installations can vary. See the 115 VAC control box Wiring/Owner’s manual OR Solar control box Wiring/Owner’s manual to wire
entrapment protection devices.
Type of wiring to be used on ALL external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better electrical,
mechanical, and flammability ratings.
Open Gate
Open Gate
Open Gate
Open Gate
Closing-Direction Photo Sensor
Closing-Direction Photo Sensor
Opening-Direction
Photo Sensor
Opening-Direction Photo Sensor
If the distance between an entrapment or obstruction
exists less than 16” from the open gate, then
entrapment protection is REQUIRED for this area.
If the distance between an entrapment or obstruction
exists less than 16” from the open gate, then
entrapment protection is REQUIRED for this area.
Entrapment protection
is RECOMMENDED for
this area.
Entrapment protection
is RECOMMENDED for
this area.
PULL to Open
PUSH to Open
IMPORTANT: Photo sensors must
use monitored resistive contacts.
See specific manufacturer's wiring
manual for more information.
(12.7 cm)