DoorKing 6006 - Swing Gate Requirements

DoorKing 6006
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6006-065-B-3-20
2
A
If distance is greater than 4 inches
(10.1 cm), entrapment protection is
REQUIRED for this area.
A
If distance is less than 16 inches
(40.6 cm), entrapment protection is
REQUIRED for this area.
B
C
B
Closed Gate
With the hinge mounted on
the corner of the pilaster,
the entrapment area is
eliminated and entrapment
protection is NOT required
for this area.
Closed Gate
Opened Gate
Opened Gate
A
Gates shall have smooth bottom edges, with vertical bottom edged
protrusions NOT exceeding 0.50 inches (1.2 cm).
C
If bottom of gate is 4” (10.1 cm) to 16” (40.6 cm)
above the ground at any part of the gate’s traveling path,
entrapment protection is REQUIRED for this area.
4 inches to 16 inches
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists.
The operator will NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH
ENTRAPMENT AREA.
Not Allowed
OK
Swing Gate Requirements
Closed Gates
This operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate
access opening. For pedestrian access in the vicinity of an automated vehicular gate, separate pedestrian access shall be
provided or available. The pedestrian access shall be in a location such that a pedestrian shall not come in contact with a
moving vehicular gate access gate during the entire path of travel of the vehicular gate. A pedestrian gate shall not be
incorporated into an automated vehicular gate panel.