Maintenance Section
105
Battery Charging
When charging, proper provision must be made for
venting of the charging gases. Battery container
lids and the covers of battery compartments must
be opened or removed. The vent plugs should stay
on the cells and remain closed.
With Battery Installed in Lift Truck
1. Refer to “Battery Access” topic for battery
access.
2. Connect the battery to the charger and charge
the battery. Observe safety warnings for
charging batteries.
3. When the battery is fully charged, disconnect
the battery from the battery charger.
4. Connect the battery to the lift truck.
5. Lower the seat and battery cover to closed
position and secure with the latch on the front of
the cover.
6. Adjust the seat position.
Indicator - Check
1. Turn the key switch to ON.
2. Check the parking brake lamp to verify
engagement of the parking brake.
3. Move the directional control forward/reverse
switch
to the NEUTRAL position.
4. Close the seat switch.
5. Check the indicator LCD display for the
discharge state of the battery and the brake oil
level.