- 20 -
2.3.6. Engine oil
Check oil level with the oil level gauge and replenish if necessary.
Check the oil level with the engine cooled. If the engine is warm, allow time for 5 ~ 10 minutes for oil
drain into the crankcase before checking oil level. The oil level must be between Max. and Min. lines
on the gauge.
Engine oil should be changed at the specified intervals.
Oil in the oil filter cartridge should be changed simultaneously.
The oil viscosity grades should be selected SAE No.15W40
The following oils are also recommended
* Use only Doosan Infracore recommended engine oil.
Engine Oil capacity
First oil change After 1,000 km (50hr) operating
Short-distance operation vehicle
(city bus, truck)
every 20,000 km
SAE No. Sulfated ash content
15W40 Bellow 0.5 %
Engine oil capacity
Engine
model
Vehicle
Oil pan inside
Total
(lit)
Max
(lit)
Min
(lit)
GL08K
Bus
ETPCA/ETPBA
17 14 20
BEB00/BEB02 14.5 10.5 20
BEB01 15.5 11.5 20
Truck 17 14 20
EA4M1008
SAE 20, 20W
SAE 10W
SAE 30
SAE 40, 50
SAE 10W - 30
SAE 5W - 20
SAE 15W - 40
SAE 10W - 40, 20W - 40, 20W - 50
-30 C
Single
grade
Ambient
temp
Multi
grade
(-20 F)
-15 C
(-0 F)
15 C
(60 F)
25 C
(80 F)
30 C
(90 F)
Engine oil viscosity - ambient temperature