DOSATRON INTERNATIONAL / 8
©
DOSATRON INTERNATIONAL / 8
hammer a protection device such
as a check valve or union ball
check must be fitted (pressure/flow
control system).
- For automatic installations, slow
opening and closing solenoid
valves are preferable.
- In an installation where a
DOSATRON serves several
sectors, the closing of one sector
and the opening of another sector
must be done at the same time
(simultaneous operation of the
solenoid valves).
4- INSTALLATION LOCATION
- The location of the DOSATRON
and concentrate container should
be accessible, but should never
present a risk of pollution or
contamination.
- It is recommended to label all
water lines with a warning about
the injected solution i.e. Not For
Human Consumption.
5- MAINTENANCE
- Rinse the injection areas after
using the DOSATRON. To do this,
insert suction tube into container
of clean water (~ 1 liter [0.264.US
GALLONS]).
.
- Routine maintenance once a
year will add to the life of your
DOSATRON. Replace the dosing
seals as well as the suction tube
annually to ensure proper injection.
6- SERVICE
- This DOSATRON was tested
prior to packaging.
- Complete maintenance and seal
kits are available.
- Call your DOSATRON distributor
for service or parts.