Connection of the IFSF module.
7.6 DIP-Switch Configuration
The illustration above shows the location of the DIP-Switch block on the Main Board.
The table that follows shows the configurations of the DIP-Switch:
Switch
Number
Description
1
OFF = single Gilbarco
ON = Double Gilbarco (required for DCD connections)
2
OFF = Internal inputs not available for alarms, but are used for other control functions
ON = Internal inputs available for alarms
3
OFF = Automatic alarm mode off
ON = Anti-theft mode (DIP-switch 2 must be OFF) with 3 + 12 V DC CN10 connection Ter-
minal and 1 0 V DC Terminal
4
OFF = Relay in normal mode
ON = Relay in reverse
5 Future Use
6
General Reset (de-energize the console, switch to ON, turn on the console, wait for the dis-
play cursor in the top left to flash, turn off the console, switch to Off, turn on the console)
IMPORTANT: The general reset results in loss of all configuration data, the his-
tory, alarms, delivery and reconciliations!
7
OFF = Reconciliation deactivated
ON = Reconciliation activated