Do you have a question about the Dräger Alcotest 9510 Standard IR and is the answer not in the manual?
Measurement Principle | Infrared spectroscopy and electrochemical |
---|---|
Resolution | 0.01 mg/L |
Operating Temperature | -5 °C to +50 °C |
Storage Temperature | -20 °C to +60 °C |
Humidity Range | 10% to 90% RH (non-condensing) |
Power Supply | Rechargeable battery or AC adapter |
Weight | Approximately 600 g (including battery) |
Display | LCD with backlight |
Interface | USB |
Printer | optional |
Compliance | OIML R 126 |
Provides essential safety guidelines for operating the Alcotest 9510 instrument.
Defines the meaning of alert icons like CAUTION and NOTICE used throughout the document.
Details the components of the Alcotest 9510, including front, side, and rear views.
Explains the functionality of the Alcotest 9510 and its measurement capabilities.
Lists required accessories and checks for operating the Alcotest 9510 instruments.
Details steps for setting up and preparing the instrument for operation.
Describes how users interact with the instrument via its screen and buttons.
Ensures conditions and trained personnel are ready for accurate breath alcohol measurements.
Guides on initiating the measurement process and preparing for breath sample collection.
Details the process of inputting operator and test subject information.
Instructions for the test subject to deliver a proper breath sample.
Describes how the measurement cycle concludes and the instrument returns to READY state.
Guide to printing a copy of the last measurement protocol.
Explains common errors encountered during measurement and their remedies.
Information on the instrument's automatic adjustment for daylight saving time.
Displays details about the installed software and hardware versions.
Allows configuration of location, time, language, and other instrument settings.
Option to rotate the screen display by 180 degrees.
Configuration settings for the internal or external printer.
Adjusts the volume and frequency of acoustic signals during measurements.
Settings for user/subject data input and sound alerts.
Stores and displays error codes and operating conditions that impede instrument use.
Allows selection of available languages and keyboard layouts.
Enables creation and selection of locations for measurement protocols.
Option to select the currently active location displayed on the screen.
Procedure for setting the instrument's date and time accurately.
Provides settings for precise analysis and requires trained operators.
Allows selection of measurement units for normal and control modes.
Enables laboratory work with increased measurement result resolution.
Lists common errors, their causes, and recommended solutions for the instrument.
Details requirements for inspections to be carried out by competent persons.
Specifies recommended and maximum intervals for instrument maintenance.
Instructions on how to replace the thermal printer paper roll.
Procedure for disconnecting power and replacing the instrument's fuses.
Guidelines for safely cleaning the instrument surfaces with a damp cloth.
Advises on precautions for safely transporting the electronic instrument.
Provides recommendations for storing the instrument in dry rooms.
Information on the proper disposal of the product, not as household waste.