EasyManuals Logo

Dragino LSN50 User Manual

Dragino LSN50
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
www.dragino.com
LSN50 LoRa Sensor Node User Manual 28 / 60
2.5 Downlink Payload
By default, LSN50 prints the downlink payload to console port.
Downlink Control Type
FPort
Type Code
Downlink payload size(bytes)
TDC (Transmit Time Interval)
Any
01
4
RESET
Any
04
2
AT+CFM
Any
05
4
INTMOD
Any
06
4
Examples
Set TDC
If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), while type
code is 01.
Payload: 01 00 00 1E TDC=30S
Payload: 01 00 00 3C TDC=60S
Reset
If payload = 0x04FF, it will reset the LSN50
CFM
Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
INTMOD
Downlink Payload: 06000003, Set AT+INTMOD=3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dragino LSN50 and is the answer not in the manual?

Dragino LSN50 Specifications

General IconGeneral
BrandDragino
ModelLSN50
CategoryAccessories
LanguageEnglish

Related product manuals