EasyManua.ls Logo

Dražice OKC 250 NTR - Page 12

Dražice OKC 250 NTR
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 12 -
Table 5
TYPE
OKC 100
NTR/HV
OKC 125
NTR/HV
OKC 160
NTR/HV
VOLUME
L
87
113
144
MAX OPERATING OVERPRESSURE IN THE TANK
MPa
0,6
MAX OPERATING OVERPRESSURE IN THE
EXCHANGER
MPa 1
ELECTRICAL CONNECTION OF CONTROL ELEMENTS
1 PE-N 230 V/50Hz
EL. PROTECTION
IP 42
MAX TEMPERATURE TUV
°C
80
RECOMMENDED HSW TEMPERATURE
°C
60
MAX WEIGHT OF THE HEATER WITHOUT WATER
kg
56
70
78
EXCHANGER HEAT TRANSFER SURFACE
m
2
1,08
1,45
1,45
RATED THERMAL OUTPUT AT HEATING WATER
TEMPERATURE 80°C AND FLOW 720 l/h
W 24000 32000 32000
TIME OF HEATING BY EXCHANGER FROM 10°C TO
60°C
min 14 14 17
STATIC LOSS
W
42
65
65