- 17 -
2.9 MOST FREQUENT FUNCTION FAILURES AND THEIR CAUSES
Other possible defects Table 7
FAILURE SYMPTOM
INDICATOR
SOLUTION
Water is cold
Light on
The temperature set
on the thermostat is too low
Heating element failure
Water is cold
Light off
no supply cable
Thermostat failure
Safety thermostat shut off
probably due to failed
operation thermostat
Water is not warm
enough
Light on
failure of one of the coils
in the element (contains 2)
Temperature of water is
not corresponding with
the set value
Light on
Defective thermostat
Water is constantly
dripping off the safety
valve
Light off
high input pressure
defective safety valve
Table 7
Do not attempt to repair the failure yourselves. Seek either expert or service help. It does
not take much for an expert to remove the defect. When making a repair appointment,
report the type and serial number you find on the performance plate of your water heater.