- 6 -
1.3 DESIGN AND GENERAL HEATER DIMENSIONS
The heater tank is made of a steel plate and tested by 0.9 MPa overpressure. The heat exchanger is tested
with a pressure of 1.5 MPa. The inside of the receptacle is enamelled. A flange is welded onto the bottom
of the tank with a flange lid screwed to it. A sealing ring is inserted between the flange lid and the flange.
Thermowells for placing a heating element and sensors of regulation thermostat and safety fuse are
located in the flange lid. An anode rod is mounted onto the M8 nut. The water reservoir is insulated
by means of polyurethane foam. Electric wiring is placed underneath the plastic removable cover.
The temperature of water can be set using the thermostat. In combined versions, a heat exchanger is
welded in the pressure tank. The heat exchanger is only intended for the heating circuit. Heater types OKCV
125-200 are produced in the right and left design.
Dimensions of the heaters –Figure 1, Figure 2, Figure 3, Figure 4, Figure 5 and Table 3, Table 4,
Table 5
TYPE