Error Message Table
ER
1,2 3 5,
'
'
6
Problem with electronic
control panel Contact Dri-
Eaz Service at 888-e67-
3235
ER 4
Check the temperature or
sensor cable, contact
Service for instructions
888-867-3235.
ER
8
Check the touchpad key.
Press and release each
key several times.
ER 9
,
Check for obstructions or
kinks in the drain hose.
READ AND SAVE THESE INSTRUCTIONS
0
PURGE.
Press the PURGE key to empty water from the pump
reservoir. During normal operation. the pump purges automatically
every six minutes, or whenever the reservoir is full. The display will
read PUMP PURGING with a numeral countdown.
To puroe the Pump manually:
1)
Turn the power off using the OFF key. and let the unit sit
plugged in for about 10 minutes. This allows water to drip
from the coils.
2)
Press PURGE to remove residual water.
Other disiblav
Defrost cycle
During normal operation, the temperature sensor detects frost forming on the
coils, causing a defrost cycle to start. The display will read DEFROST ON
Dehumidification stops during the defrost cycle. When the unit completes the
cycle, the display returns to DEHUMIDIFIER ON.
Error messages
When the display menu shows the error message "GET SERVICE,' followed
by "ER01" or another numeral. follow these steps:
1.
Unplug the unit and then plug it back in. This may re-set the
electronics
2. If that does not fix the problem. try the solution (if one is listed) in
the "Error Message Table
-
to the left
3. If that does not fix the problem, contact the Dri-Eaz Service
Department at 888-867-3235.
Maintenance
MAINTENANCE INTERVALS
ik WARNING
ELECTRIC SHOCK
HAZARD
Unplug any DrizAir dehumidifier before performing maintenance.
Before Each Use
Inspect the electrical cord for damacte.
Look for fraying. cuts, etc. Do not
use the unit if you find any. Call Dri-Eaz for the nearest Service Center
888-867-3235.
Inspect filter.
Look for accumulated dust and dirt that would restrict airflow
through the filter into the unit. If any is visible, vacuum out the debris.
Do
not wash the filter,
as it will reduce the effectiveness of the electrostatic
material.
IMPORTANT: Replace
the filter whenever
It has been vacuumed clean 3 times
It has been used on a mold remediation
job
Monthly
Remove housing, in order to locate the coils, catch basin, float shaft, and
drain hose.
5
Al
WARNING
lvb
ELECTRIC SHOCK
HAZARD
Unplug unit before performing
any maintenance.
Never use a water hose or pres-
sure washer to clean coils, water
could enter the electrical com-
partment causing a shock
hazard.
Follow cleaning instructions in
manual.
Air Marketing Group LLC
141 Kinderkamack Rd. Park Ridge NJ 07656 Tel
.
201-782-1782 Fax 201-782-1783 Web wwwamgair corn Email. info@arngair corn