F388 Owner’s Manual
Dri-Eaz
®
EnviroBoss
1400 (115V)
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: 360-757-7950
www.dri-eaz.com
The EB1400 is a portable cooling, heating and dehumidification system. The unit may be
ducted for directing cooled or heated air into specific spaces.
READ AND SAVE THESE INSTRUCTIONS
Read and understand manual before operating.
ELECTRIC SHOCK HAZARD
WARNING! Unit must be grounded.
Use indoors only.
Keep out of water.
Keep electrical components dry. If they get wet, allow
them to dry before using the EB1400.
Insert three-prong plug on power cord into a matching
electrically grounded outlet. Never cut off third prong.
FIRE HAZARD
Keep air intakes clear of obstructions and dirt. Reduced
airflow can cause motor to overheat. Keep away from
draperies or other material that could block air intakes.
See maintenance instructions.
Keep air filter clean. Keep filter clear of clogging, oil,
grease or other contaminants that can be drawn into the
EB1400.
SAFETY INSTRUCTIONS
WARNING! Unplug unit before opening housing for
cleaning or servicing.
Turn off unit and unplug before lifting or moving.
Handle the unit carefully. Always operate the unit on a
stable, level surface. Do not drop, throw, or place where it
could fall. Rough treatment can damage the unit, and may
create a hazardous condition or void the warranty.
Inspect the power cord before use. If cord is damaged, do
not use. Replace with a cord of the same type and
amperage rating. Protect cord from damage by turning off
unit before unplugging. Always grasp the plug (not pulling
on the cord) to unplug.
The unit is designed to operate on 115V/60 Hz. Make sure
that the electrical outlet is grounded.
Secure during transport to prevent sliding and possible
injury to vehicle occupants.
W
ARNING
Keep children away from unit. Be sure unit is inaccessible
to children when unattended.
Do not attempt to disassemble or repair the unit. For
Authorized Service Centers, go to
www.dri-eaz.com/howtobuy or call Dri-Eaz Service at
800-932-3030.
INTRODUCTION
The EB1400 is a versatile unit providing dehumidification, 1-ton
cooling with 470 CFM across the evaporator and 750 CFM
across the condenser, plus focused heating and ventilation.
The unit can be ducted for spot cooling and directing
conditioned air or heat into specific spaces while filtering room
air and pumping out condensate.
FEATURES:
Ducts to and from unit for heating and cooling. Note: Duct
adapters for condenser inlet and outlet and evaporator
outlet. No duct adapter for evaporator inlet.
Refrigeration system that dehumidifies while it heats or
cools
Uniform 8" ducting size for all outlets
Digital temperature control
Durable rotomolded duct rings and housing
Wheel casters and handle for ease of transport
07-01626B 2008-05 Copyright 2007 Dri-Eaz Products, Inc. 1
Question and Answer IconNeed help?

Do you have a question about the Dri-Eaz EB1400 and is the answer not in the manual?

Dri-Eaz EB1400 Specifications

General IconGeneral
BrandDri-Eaz
ModelEB1400
CategoryDehumidifier
LanguageEnglish

Summary

Safety Warnings and Precautions

Electric Shock Hazard

Warning about grounding, indoor use, keeping components dry, and proper outlet connection.

Fire Hazard

Caution regarding clear air intakes, motor overheating, and keeping away from blocking materials.

General Safety Instructions

Unplug before cleaning/servicing, handle carefully, inspect power cord, and verify grounding.

Product Overview and Features

Introduction

Introduces the EB1400 as a portable cooling, heating, and dehumidification system.

Key Features

Lists capabilities like ducting, refrigeration system, digital controls, and durable construction.

Setup and Operating Instructions

Operating Range

Specifies the recommended operating temperature range for the unit.

Compressor Protection

Explains automatic compressor protection to avoid damage from short cycling.

Getting Started

Provides initial steps for placement and starting the unit for cooling or heating.

Thermostat Operation

Digital Controls Overview

Details the digital display and control buttons for temperature and fan settings.

Testing Thermostat

Instructions for testing the heating and cooling functions of the thermostat.

Viewing and Changing Set Temperature

Guide on how to view and adjust the desired set point temperature.

Advanced Functions and Applications

High Temperature Safety Switch

Explains the automatic shut-off feature at high room temperatures.

Non-Volatile Memory

Describes how settings are retained during power outages.

Resetting Thermostat

Instructions to reset the thermostat to factory default settings.

Ducting Instructions

Guidance on using ducting for air delivery and specific ducting requirements.

Maintenance and Specifications

Before Each Use Maintenance

Check power cord for damage before operating the unit.

Weekly Maintenance

Inspect and clean the front filter for optimal performance.

Monthly Maintenance

Inspect exterior, clean housing, and inspect back filters periodically.