07-01802C (F412-230V) 2013-01 Warranty 07-00427 12 Dri-Eaz Products, Inc.
Stand the unit upright and remove the front cover as
described under “To disassemble the unit for cleaning coils
and heat exchange block,” p. 8.
Now remove the four rear panel
3
8
in. bolts.
Tip the top of the rear panel away from the unit and lay it
flat in front of the unit. It is not necessary to disconnect the
wire harness from the rear panel or from the electrical box.
Clean the horizontal cold (evaporator) coil. Use a vacuum
or condenser coil cleaner. If using the coil cleaner, use a small
container to capture runoff from the drain basin.