07-01802C (F412-230V) 2013-01 Warranty 07-00427 16 Dri-Eaz Products, Inc.
INSPECTING THE CONTROL PANEL
Using a Philips screwdriver, remove the four baseplate
retaining screws.
Carefully lift out the control panel. The sensor connections
are located on the underside of the panel.
The sensor connections are labeled “OUT T” (outlet
temperature sensor) and “DEFR” (defrost sensor).
Note that the DEFR cable is marked with silver paint. Make
sure each cable is connected in the correct location and that
they are firmly seated.
The DIP switch is located in the center of the panel. Do not
change the the DIP settings unless instructed by qualified
service personnel to do so.
NOTICE! The control panel circuit board contains sensitive
electronic components. Handle with care at all times. To
avoid damaging the circuit board with a static electricity
discharge, do not touch the circuitry with your finger or
tool, and do not place any tape or other material in contact
with the circuit board.
When inspection is complete, replace the controller in the housing and tighten down the screws. Do not overtighten.