4 Securing the Premises
16
6. If using an LED or ICN series keypad, the will light and the bypassed zone
#s will be shown. If the system is ready to arm the Ready indicator will be
lit. When arming the system the following message briefly displays.
* Warning *
Bypass Active
To Bypass All Open Zones LCD Display
1. Press to enter the function menu.
Press (*) for <>
Zone Bypass
2. Press or . If required enter your [access code].
Zone Bypass <>
(*) To Bypass
3. Press
OR
Scroll to Bypass Options and press . Scroll to Bypass Op. Zones and
press . All open zones will now be bypassed.
Press (*) for <>
Bypass Op. Zones
4. To exit bypassing mode press .
5. If using an LED or ICN series keypad, the will light and the bypassed
zones #s will be shown. If the system is ready to arm the Ready indicator
will be lit. When arming the system the following message briefly displays.
* Warning *
Bypass Active
To Recall the Last Bypassed Zones LCD Display
1. Press to enter the function menu.
Press (*) for <>
Zone Bypass
2. Press or . If required enter your [access code].
Zone Bypass <>
(*) To Bypass
3. Press
OR
Scroll to Bypass Options and press . Scroll to Bypass Recall using the
keys and press .
Press (*) for <>
Bypass Recall
then
Bypass Recalled
Zones Bypassed
4. To exit bypassing mode press .
5. If using an LED or ICN series keypad, the will light and the bypassed zone
#s will be shown. If the system is ready to arm the Ready indicator will be
lit. When arming the system the following message briefly displays.
* Warning *
Bypass Active
To Clear the Bypass Indication from All Zones LCD Display
1. Press to enter the function menu.
Press (*) for <>
Zone Bypass
2. Press or . If required enter your [access code].
Zone Bypass <>
(*) To Bypass
3. Press
OR
Scroll to Clear Bypasses using the keys and press . All
Bypassed zones will now be open.
Press (*) for <>
Clear Bypasses
then
Bypass Cleared
Zones Unbypassed
4. To exit bypassing mode press .
To Bypass Individual Zones (Continued) LCD Display
*
*
1
9
9
8
*
*
#
*
*
1
9
9
9
*
*
#
*
*
1
0
0
0
*
#

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals