Section 2: Access Codes
cannot program other Supervisor codes, or System Master codes. For a
list of the other user options that are enabled for this code, see Table 2-1.
Duress Codes
If the “Duress” user option is enabled, the code will become a Duress
code. When this code is entered, the system will send a duress signal to
the monitoring station. Make sure that the Arm and Disarm user options
are also enabled for this code.
One-time Use Codes
If the “One-time Use” option is enabled, the code will become a One-time
Use code. The code can be used to disarm assigned partitions. When a
user arms the system using a One-Time Use code, the panel will erase the
code once the Exit Delay expires; after this time, the code cannot be used
again. Make sure that the Arm and Disarm user options are also enabled
for this code.
Log Only Codes
A “Log Only” code will only create an entry in the event buffer when
entered at a keypad. Example: a log-only code may be used by a guard to
record the time that they checked each area of the premises.
To create a log-only code, disable all the access code options for the code.
Temporary Codes
A “Temporary code” is an access code that can be turned on or off by
partition using the “T-Code” function key. Any code with the temporary
code attribute enabled will work this way.
To turn temporary codes on for a partition, press and hold the “T-Code”
function key at a keypad assigned to the partition. You may need to enter
an access code after pressing the “T-Code” key.
If enabled for your access code, you can also turn temporary codes on
and off for any partition by entering [*][6][access code][0][3].
2.7 Installer Programmed Codes
These are access codes that are programmed by your installer. Talk to
your installer for more information regarding these codes.
Second Master Code: This code has the same properties as the
System Grand Master code. Only your installer can program this
code.
Walk Test Code: The Walk Test code is used to access to the walk test
mode. See Section 5.1 “Walk Test” for instructions on performing a
walk test.
Guard Code: This code is only valid when a partition is disarmed
and for a programmed amount of time after a partition is armed
using the Guard code. Only your installer can program the Guard
code.

Table of Contents

Other manuals for DSC MAXSYS PC4020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC MAXSYS PC4020 and is the answer not in the manual?

DSC MAXSYS PC4020 Specifications

General IconGeneral
Partitions8
Event Buffer1000 events
Keypads16
Power Supply16.5V, 40VA transformer
Battery Backup12V 7Ah (typical)

Related product manuals