EasyManuals Logo

DSC PC1565 - VERSION 2.3 User Manual

DSC PC1565 - VERSION 2.3
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
1
Section 1: System Introduction
1.1 Specifications
Downloading Software Support
PC1565 v2.3 uses DLS-1 v6.7 and up.
Flexible Zone Configuration
Six fully programmable zones
System expandable to 32 zones using:
up to 8 keypad zone inputs and/or
up to 32 wireless zones with the PC5132 wireless
expansion module
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
27 zone types; 8 programmable zone attributes
Normally closed, single EOL and double EOL zone wiring
32 wireless zones with the PC5132 Wireless Receiver
Audible Alarm Output
700mA Supervised Bell Output (current limited at 3 amps),
12V
DC
Steady or Pulsed Output
EEPROM Memory
Does not lose programming or system status on complete
AC and Battery failure
Programmable Outputs
One programmable voltage output and one programmable
voltage output/input; 20 programmable options
PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
550 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components
replace fuses
Supervision for loss of AC power, low battery
Internal clock locked to AC power frequency
Power Requirements
Transformer = 16.5 V
AC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed lead
acid battery
Remote Keypad Specifications
Keypads available:
- PC5509 eight zone LED keypad
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- PC5516Z sixteen zone LED keypad with zone input
- PC5532Z thirty-two zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
All keypads (except PC5509) have five programmable
function keys
Connect up to eight keypads
4-wire (Quad) connection to Keybus
Built in piezoelectric buzzer
Digital Communicator Specifications
Supports major communication formats including SIA and
Contact ID
Event-initiated personal paging
Three programmable telephone numbers
Two account numbers
Supports LINKS1000 cellular communication
Supports LINKS2X50 long range radio transmitter
DTMF and pulse dialing
DPDT line seizure
Anti-jam feature
Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC1565 continuously monitors a number of possible trou-
ble conditions including:
AC power failure • AUX Power Supply Trouble
Fault by zone • Loss of internal clock
Tamper by zone • Bell output trouble
Fire trouble • Telephone line trouble
Failure to communicate • Low battery condition (panel)
Low battery by zone (wireless)
Module fault (supervisory or tamper)
False Alarm Prevention Features
Audible Exit Delay • Quick Exit
Audible Exit Fault • Cross Zone Burglary Alarm
Communication Delay • Rotating Keypress Buffer
Urgency on Entry Delay • One Restart of Exit Delay
Additional Features
Auto Arm at specified time
Keypad-activated alarm output and communicator test
All modules connect to the system via a four wire Keybus
up to 1000’/305m from main panel
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad and DLS-1 software
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
Uploading and downloading capability
Local downloading capability through the use of the
PC-LINK adaptor
Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to pre-
vent control panel damage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PC1565 - VERSION 2.3 and is the answer not in the manual?

DSC PC1565 - VERSION 2.3 Specifications

General IconGeneral
Partitions2
Event Buffer128 events
CommunicatorBuilt-in
PGM Outputs2 (expandable)
Alarm System TypeWired
Battery Backup12VDC, 4Ah
Keypads Supported8
CommunicationPhone line
Power Supply16.5VAC, 40VA
Operating Temperature0°C to 49°C (32°F to 120°F)