EasyManuals Logo

DSC PC1565 - VERSION 2.3 User Manual

DSC PC1565 - VERSION 2.3
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
46
[61] Second User Display Mask
Default Option ON OFF
OFF I_______I 1 Installer Programming prompt ON Installer Programming prompt OFF
ON
I_______I 2 Stay Arm prompt ON Stay Arm prompt OFF
ON
I_______I 3 Quick Arm prompt ON Quick Arm prompt OFF
ON
I_______I 4 Interior Arm prompt ON Interior Arm prompt OFF
OFF
I_______I 5 Quick Exit prompt ON Quick Exit prompt OFF
ON
I_______I 6 View Event Buffer prompt ON View Event Buffer prompt OFF
OFF
I_______I 7-8 For future use
[62] Third User Display Mask
Default Option ON OFF
ON I_______I 1 System Test prompt ON System Test prompt OFF
ON I_______I 2 Time and Date prompt ON Time and Date prompt OFF
ON I_______I 3 Auto-Arm Control prompt ON Auto-Arm Days prompt OFF
ON
I_______I 4 Auto-Arm Time prompt ON Auto-Arm Time prompt OFF
ON I_______I 5 Download Enable prompt ON Download Enable prompt OFF
ON I_______I 6 Bright Control prompt ON Bright Control prompt OFF
ON I_______I 7 Contrast Control prompt ON Contrast Control prompt OFF
ON I_______I 8 Buzzer Control prompt ON Buzzer Control prompt OFF
[63] Downloaded LCD Message Duration
Default: 003 I_______I_______I_______I (Valid entries are 000-255, 000=Unlimited Message Display. This number represents the number of times
the Downloaded message is cleared by pressing any key while the message is up after timeout)
[64] Key Options
Default Option ON OFF
ON I_______I 1 [F]ire Keys enabled [F]ire Keys disabled
ON
I_______I 2 [A]uxiliary Keys enabled [A]uxiliary Keys disabled
ON I_______I 3 [P]anic Keys enabled [P]anic Keys disabled
OFF I_______I 4-8 For future use
[65] Fourth User Display Mask
Default Option ON OFF
ON I_______I 1 User Initiated Call-up Prompt ON User Initiated Call-up Prompt OFF
OFF I_______I 2 For future use
OFF I_______I 3 For future use
ON
I_______I 4 Command Output #1 prompt ON Command Output #1 prompt OFF
ON I_______I 5 Command Output #2 prompt ON Command Output #2 prompt OFF
OFF I_______I 6-8 For future use
[66] Keypad Options
Default Option ON OFF
ON I_______I 1 Display Access Code when Programming Display ‘X’ when Programming
ON I_______I 2 Local Clock Display Enabled Local Clock Display Disabled
OFF I_______I 3 Local Clock Displays 24 Hour time Local Clock Displays AM/PM
ON I_______I 4 Auto Alarm Memory Scroll Enabled Auto Alarm Memory Scroll Disabled
OFF
I_______I 5-8 For future use
[97] View Software Version
[98] Initiate Global Label Broadcast
All LCD programming is done per keypad. If more than one LCD keypad are present on the system, and the PC5400 receives labels, labels pro-
grammed at one keypad can be broadcast to all other LCD keypads. Perform the following procedure in order to broadcast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter Installer’s Programming, then enter Section [98] at the keypad that was programmed. The keypad will now broadcast all the informa-
tion programmed to all the other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
[99] Reset LCD EEPROM to Factory Defaults
ASCII Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PC1565 - VERSION 2.3 and is the answer not in the manual?

DSC PC1565 - VERSION 2.3 Specifications

General IconGeneral
Partitions2
Event Buffer128 events
CommunicatorBuilt-in
PGM Outputs2 (expandable)
Alarm System TypeWired
Battery Backup12VDC, 4Ah
Keypads Supported8
CommunicationPhone line
Power Supply16.5VAC, 40VA
Operating Temperature0°C to 49°C (32°F to 120°F)