29
PC3000 Version 7.7
[13] Reporting Codes for Opening (Disarming) via Access Codes 1 to 8
Page 16
Access Code 1 Access Code 5
Access Code 2 Access Code 6
Access Code 3 Access Code 7
Access Code 4 Access Code 8
[14] Reporting Codes for Opening (Disarming) via Access Codes 9 to 16
Page 16
Access Code 9 Access Code 13
Access Code 10 Access Code 14
Access Code 11 Access Code 15
Access Code 12 Access Code 16
[15] Reporting Codes for Miscellaneous Functions
Page 16
Partial Closing*** * Priority alarms/restorals
Keypad Panic Alarm [P]* * * Maintenance alarms/restorals see section [33]
Keypad Fire Alarm [F]* *** Transmission reports with sections [11] to [14]
Keypad Auxiliary Alarm [A]* (openings/closings)
Keypad Panic Restoral [P]*
Keypad Fire Restoral [F]*
Keypad Auxiliary Restoral [A]*
Periodic Test Transmission**
[16] Zone Definitions for Zones 1 to 8
Page 16
Note: When defining zones, ASSIGN DELAY ZONES FIRST to zones 1, 2, 3....then assign the other types to the
remaining zones in any order desired.
Default 1st Digit 2nd Digit
00 Zone 1 0 = Slow, audible 0 = Delay
0 1 Zone 2 1 = Slow, silent 1 = Instant
0 1 Zone 3 2 = Fast, audible 2 = Interior
0 1
Zone 4 3 = Fast, silent 3 = Interior...Home-Away
0 1 Zone 5 4 = 24 hr...Bell
0 1
Zone 6 5 = 24 hr...Bell/Buzzer
0 1 Zone 7 6 = 24 hr...Buzzer
0 1
Zone 8 7 = Double delay
8 = 4x Delay
9 = Day
A = Delay...Home-Away
WWW.DIYALARMFORUM.COM