4
POST IN A PROMINENT LOCATION instructions to be followed in
the event the user smells gas. This information shall be obtained by
consulting the local gas supplier.
FOR YOUR SAFETY:
Do not store gasoline or other flammable vapors or liquids in the vicinity of this or
any other appliance.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
6/13 GAS CONVECTION OVEN
Specifications
HEATING VALUE
NATURAL GAS PROPANE GAS
1000 BTU 37.3 MJ/m
3
2550 BTU 95.0 MJ/m
3
SPECIFIC GRAVITY 0.63 0.63 1.53 1.53
GAS PRESSURE AT
MANIFOLD
3.5” W.C 0.87 kPa 10” W.C. 2.49 kPa
OVEN INPUT
STANDARD DEPTH
PER BURNER 20,000 BTU/HR 5.9 kW 20,000 BTU/HR 5.9 kW
PER OVEN 40,000 BTU/HR 11.8 kW 40,000 BTU/HR 11.8 kW
DEEP DEPTH
PER BURNER 23,000 BTU/HR 6.8 kW 23,000 BTU/HR 6.8 kW
PER OVEN 46,000 BTU/HR 13.5 kW 46,000 BTU/HR 13.5 kW
BURNER ORIFICE SIZE
STANDARD DEPTH #44 2.18 mm #55 1.32 mm
DEEP DEPTH #43 2.26 mm #54 1.40 mm