Installation and Operation of: DUKE TSC Proofer Oven with Touch Screen Controls
Figure: Restraining Device Kit (Part # 153586)
HAZARDOUS VOLTAGE RISK OF ELECTRIC SHOCK
DISCONNECT POWER TO SERVICE COMPARTMENT
THIS RESTRAINING DEVICE MUST ALWAYS
BE CONNECTED WHEN THE APPLIANCE IS IN
SERVICE. DISCONNECT ONLY FOR SERVICING
AND/OR CLEANING, THEN RECONNECT WHEN
THE APPLIANCE HAS BEEN RETURNED TO
ITS NORMAL POSITION.
INSTALLATION
1. This unit can be converted to other mains
supply congurations by Duke Manufacturing
approved service personnel. Call Duke Service
Department for action if electrical rating tag
information is not compatible with the available
mains supply.
2. This unit is supplied with the national
and international specied water supply
interconnection. Backow prevention
protection is optionally supplied as a factory
installed option or as an add-on kit. Local
regulation variances or additional requirements
must be evaluated prior to installation. New
water supply line interconnection must be used
when installing this unit.
Maximum / minimum supply pressure
specication is 65PSI (450KPa) / 40PSI (275KPa)
for all system plumbing components. See
INSTALLATION OF WATER FILTER section prior
to water supply interconnect.
3. This appliance must be secured to building
structure. A restraining device kit (#153586)
provided with the unit limits the movement of
the appliance without transmitting stress to the
mains supply. Installation instructions are in the
kit.
4. IMPORTANT: A minimum clearance of
6"(152mm) from the top of unit to the ceiling
must be provided. Unit may be installed with
minimal clearance on one side and rear of the
cabinet.
5. Check the swing of the door. The hinge side can
be changed by referring to the Reversing Oven
Door Swing Direction section of this manual.
6. Check the door seal and make sure both doors
close completely. If they do not close and seal
properly, refer to the Door Gasket Adjustment
section of this manual.
INSTALLATION  continued
7. Place the wire racks in the oven and proofer.
8. Unit can be mechanically attached to wall using
optional wall-mounting brackets. Optional
wall-mounting brackets are not required for safe
operation of the unit. Refer to Installation of
Wall Brackets section of this manual for the
instructions on Installation of Wall Brackets to
the wall.