EasyManua.ls Logo

Dunkirk DCC-205 - User Manual

Dunkirk DCC-205
139 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Manufactured by:
ECR International Inc.
2201 Dwyer Avenue, Utica, NY 13501
Tel. 800 325 5479
www.ecrinternational.com
DCB-100
DCC-115
DCB-125
DCC-150
DCB-165
DCC-205
CONDENSING
WALL MOUNTED
GAS FIRED BOILER

Table of Contents

Other manuals for Dunkirk DCC-205

Questions and Answers

  • R
    Robert CunninghamSep 9, 2025
    What to do if Dunkirk DCC-205 has gas valve command fault?
    • A
      Amy FoleySep 9, 2025
      If your Dunkirk Boiler has a gas valve command fault, verify all cables and replace the PCB.
  • H
    hoffmanrandallAug 22, 2025
    What to do if safety thermostat tripped in Dunkirk DCC-205?
    • A
      Ashley AllenAug 23, 2025
      If the safety thermostat has tripped on your Dunkirk Boiler due to over temperature, which may be caused by a blocked pump or air in the heating circuit, check the safety thermostat and its cable. Also, verify the correct circulation of water and the pump.
  • E
    Eric WarrenAug 25, 2025
    How to fix combustion test alarm during calibration of Dunkirk DCC-205 Boiler?
    • D
      Dustin YoungAug 25, 2025
      If your Dunkirk Boiler's combustion test triggers an alarm during commissioning or calibration, examine the flame sensor. Check for any obstructions in the flue pipe and look for recirculation issues. Verify the gas pressure, gas orifice, and gas quality. You may need to perform automatic and manual calibration functions.
  • M
    Michael DuarteAug 26, 2025
    What to do if hydraulic pressure is too high in Dunkirk DCC-205?
    • J
      Joshua GonzalezAug 26, 2025
      If the hydraulic pressure in your Dunkirk Boiler is too high, relieve the pressure using the relief valve or by draining the system. Ensure that the water feed is operating correctly.
  • T
    Todd HallAug 27, 2025
    How to fix low hydraulic pressure in Dunkirk DCC-205 Boiler?
    • K
      Katrina MartinAug 27, 2025
      If the hydraulic pressure in your Dunkirk Boiler is too low, refill the heating system by opening the cold water tap.
  • L
    Lisa LewisAug 29, 2025
    What to do if NTC flue sensor tripped in Dunkirk DCC-205 Boiler?
    • H
      hallherbertAug 29, 2025
      If the NTC flue sensor in your Dunkirk Boiler has tripped due to over temperature, check the thermostat and ensure correct water circulation and pump operation. Also, check the status of the primary exchanger.
  • W
    wilsonreginaldSep 17, 2025
    How to check Flue NTC heat exchanger sensor fault in Dunkirk Boiler?
    • H
      Heather ChenSep 18, 2025
      If you're encountering a Flue NTC heat exchanger sensor fault in your Dunkirk Boiler, check the sensor and its cable.
  • D
    davisericSep 18, 2025
    How to check Outdoor sensor fault in Dunkirk DCC-205 Boiler?
    • K
      kstewartSep 19, 2025
      If you're encountering an Outdoor sensor fault in your Dunkirk Boiler, check the sensor and its cable.
  • C
    Carl DavisSep 7, 2025
    How to program PCB in Dunkirk Boiler?
    • J
      Jason AshleySep 8, 2025
      If the PCB of your Dunkirk Boiler is not programmed, follow the instructions provided with the control board replacement kit. If you need further assistance, call technical service.
  • J
    Jared TrevinoSep 4, 2025
    What causes communication problem between Dunkirk Boiler board and control unit?
    • K
      Kristie ShawSep 4, 2025
      If you're experiencing a communication problem between the boiler board and control unit of your Dunkirk Boiler, it's likely due to a short circuit on the wiring. Check the cable between the control unit and the boiler.

Summary

Important Safety Information

1. Safety Information

Essential safety precautions, hazard symbols, and warnings.

3 - COMPONENT LISTING

Dunkirk DCB 100 Components

Identifies and illustrates key parts of the DCB 100 boiler.

9 - START UP PROCEDURE

9.1 Central Heating System Connections - HEAT ONLY

Steps for connecting the heating-only system to the boiler.

9.5 Control Panel

Overview of the boiler control panel interface and its functions.

10 - OPERATING INSTRUCTIONS

10.1 Testing For Gas Leaks And Purging The Gas Supply

Steps for safely testing gas connections and purging the supply.

11 - GENERAL MAINTENANCE AND CLEANING

11.1 Beginning of Each Heating Season

Pre-season checks for safe boiler operation and efficiency.

12 - RATINGS AND CAPACITIES

13 - TROUBLE SHOOTING

LOW WATER CUTOFF

ERROR CODE TABLE

IMPORTANT INFORMATION

Dunkirk DCC-205 Specifications

General IconGeneral
BrandDunkirk
ModelDCC-205
CategoryBoiler
LanguageEnglish

Related product manuals