What to do if Dunkirk Boiler has gas valve command fault?
- Bbrandon45Sep 9, 2025
If your Dunkirk Boiler has a gas valve command fault, verify all cables and replace the PCB.
What to do if Dunkirk Boiler has gas valve command fault?
If your Dunkirk Boiler has a gas valve command fault, verify all cables and replace the PCB.
What to do if safety thermostat tripped in Dunkirk Boiler?
If the safety thermostat has tripped on your Dunkirk Boiler due to over temperature, which may be caused by a blocked pump or air in the heating circuit, check the safety thermostat and its cable. Also, verify the correct circulation of water and the pump.
How to fix combustion test alarm during calibration of Dunkirk DCB-165?
If your Dunkirk Boiler's combustion test triggers an alarm during commissioning or calibration, examine the flame sensor. Check for any obstructions in the flue pipe and look for recirculation issues. Verify the gas pressure, gas orifice, and gas quality. You may need to perform automatic and manual calibration functions.
What to do if hydraulic pressure is too high in Dunkirk DCB-165?
If the hydraulic pressure in your Dunkirk Boiler is too high, relieve the pressure using the relief valve or by draining the system. Ensure that the water feed is operating correctly.
How to fix low hydraulic pressure in Dunkirk Boiler?
If the hydraulic pressure in your Dunkirk Boiler is too low, refill the heating system by opening the cold water tap.
What to do if NTC flue sensor tripped in Dunkirk DCB-165?
If the NTC flue sensor in your Dunkirk Boiler has tripped due to over temperature, check the thermostat and ensure correct water circulation and pump operation. Also, check the status of the primary exchanger.
How to check Flue NTC heat exchanger sensor fault in Dunkirk DCB-165?
If you're encountering a Flue NTC heat exchanger sensor fault in your Dunkirk Boiler, check the sensor and its cable.
How to check Outdoor sensor fault in Dunkirk DCB-165?
If you're encountering an Outdoor sensor fault in your Dunkirk Boiler, check the sensor and its cable.
How to program PCB in Dunkirk Boiler?
If the PCB of your Dunkirk Boiler is not programmed, follow the instructions provided with the control board replacement kit. If you need further assistance, call technical service.
What causes communication problem between Dunkirk DCB-165 board and control unit?
If you're experiencing a communication problem between the boiler board and control unit of your Dunkirk Boiler, it's likely due to a short circuit on the wiring. Check the cable between the control unit and the boiler.
Provides critical safety warnings and precautions for installation and operation.
Provides instructions and considerations for mounting the boiler on a wall.
Specifies requirements and guidelines for terminating the boiler's vent system.
Provides detailed instructions for installing coaxial venting systems.
Provides instructions on connecting the condensate drain for safe and proper operation.
Explains the installation and wiring of an optional low water cutoff device.
Provides guidance on selecting and installing appropriate gas piping for optimal operation.
Details the procedure for performing leak checks on gas piping connections.
Guides through the initial system start-up process, including filling and purging.
Explains the critical step of filling the condensate trap before boiler operation.
Outlines the procedure for first-time boiler commissioning and gas type identification.
Details the steps for the automatic calibration process to optimize boiler performance.
Guides the user through manual calibration adjustments for combustion parameters.
Explains the de-aeration process to remove air from the heating circuit.
Details how to set up the boiler for different gas types like Natural Gas or LPG.
Guides on adjusting CO2% for optimal combustion performance.
Explains how to adjust the boiler's maximum heating power output.
Details the procedure for testing gas leaks and purging the gas supply.
Details regular servicing procedures and checks for maintaining peak boiler efficiency.
Provides instructions for cleaning and replacing key boiler components.
Guides through the final steps of commissioning the boiler system after installation.
Lists common error codes, their meanings, and procedures for resetting the boiler.
Continues the list of error messages and troubleshooting steps for the boiler.
Lists anomalies that appear specifically in the fault history log.
A table for installers to record and analyze anomaly codes and system status.
Lists initial checks to perform when troubleshooting boiler errors.
Provides a flowchart for diagnosing and resolving issues in the central heating system.
Offers a troubleshooting flowchart for diagnosing and resolving domestic hot water system issues.
Details troubleshooting steps for power supply and PCB issues.
Covers troubleshooting for pump and wiring related to the PCB.
Addresses issues related to fan connections, winding, and PCB.
Addresses troubleshooting for temperature sensors and potential replacements.
Guides on troubleshooting gas at the burner and potential gas valve or PCB issues.
Covers troubleshooting for ignition, electrodes, and condensate traps.
Details troubleshooting for gas supply pressure, flame sensing, and condensate switches.
Addresses issues related to overheat thermostat and system faults.
Covers troubleshooting for CH system pressure issues.
Details troubleshooting for pump circulation and temperature sensors.
Addresses issues related to 3-way valve connections and motor.
Troubleshoots issues with main water filter, assembly, and hall effect sensors.
Focuses on troubleshooting temperature sensors and heat exchangers.