5.3.3 Programming interval control
pH
pH
pH
After pressing while is flashing, and are displayed and the hour digits are flashing.
To adjust the interval On time,
use the or button to set the hours between 0 and 23.
Press , the minutes digits will flash.
Use the or button to set the minutes between 0 and 59.
Press , the seconds will flash .
Use the or button to set the seconds between 0 and 59.
and are displayed and the hour digits flash.
To adjust the interval OFF time, use the or button to set the hours between 0 and 96
Please note: 24 means every day, 48 every two days, 72 every three days, 96 every four days.
Press
, the minutes will flash .
Use the or button to set the minutes between 30 and 59*.
Acknowledge with .
If
Time
flashes again, press for three seconds to finish programming and return to the operating mode.
* Settings between 0 and 59 are only possible with intervals of 1 hour or longer. For shorter intervals, a mini-
mum of 30 minutes is preset by the manufacturer to protect electronic components.
Please note: The first interval control is triggered immediately after the system returns to the operating mode.