ADVANCED SETTINGS PAGE
Password Level 2
Controls
Functions
Autoheight
Off/On
Allows the autoheight sensing for pallet load height variations. (There are
two limit switches on the carriage with adjustable stops on the vertical
boom as safety override). When the switch is at OFF, the system will look
at the top limit switch instead. Even if the switch is ON and the carriage
reaches the top limit switch first, the carriage will still stop.
Run At ### RPM When No
Load Waiting To Be Wrapped
This selector determines the speed for the wrapper to use when in
Energy Saving Mode. Applies to the rotation speed as well as the
carriage up/down speeds.
Forklift Load Picked Up Time
r
Used to change the delay on the forklift load picked up timer. This delay is
the time before a new load can be received for pick-up on a conveyor.
Forklift Load Dropped Time
r
Used to change the delay on the forklift load dropped timer. This delay is
the time before a conveyor will start moving after load is dropped.
Forklift Cleared Time
r
Used to change the delay on the forklift cleared timer. This delay is the
time before a conveyor can move after photoeye has been cleared.