FENCE ENTRY/EXIT PROCEDURE
Please use this procedure when entering and exiting the safety fencing.
1. Make sure the wrapper zone is in stop mode.
2. If not, press Start/Stop push button to put machine in stop mode.
3. Make sure the key-switch green light is off (which indicates that the door is unlocked).
4. Open the fence door.
5. Carry out the lock out/tag out (LOTO) procedure, if applicable.
6. Carry out the work to be done inside the safety fencing zone.
7. Exit the safety fencing zone making sure no person or object is left behind.
8. Remove LOTO protection, if applicable.
9. Close the fence door.
10. Follow the instructions as indicated on the HMI.
11. When the wrapper zone in start mode, all doors are locked (green light is lit).