LUBE STATION
The greaser is controlled by a PLC output and should be greasing for 60 seconds after a specific number of hours.
The number of hours between lubrications is factory set according to multiple factors.
Inspect the grease container of the lube station once a month and refill with EP2 grease as recommended by Wulftec
unless you have requested a different type of grease in your system (ex. FDA-approved) or if your operating
environment requires a different type of grease (ex. cold temperature environment). The lube station needs to be
refilled before it is empty. To fill the container, use the fitting located on the front side until you reach the maximum
line.
CONVEYOR
When required to stand on the conveyor for any reason, power to the machine must be cut, then, put a proper
thickness board, large as the conveyor, on the top of the conveyor for as long as the work requires. Do not let the
board’s edges overhang over the conveyor sides to avoid turning over.
FILM CLAMP
When the machine starts doing film tails, remove the film build-up that has accumulated on the clamp jaw. To do this,
clean using a lubricant (ex: WD-40™ or any type of silicon spray) and an abrasive pad (ex: Scotch-Brite™) until build-
up is removed.
HEAT WIRE
When replacing the heat wire, only replace with resistive wire as any other type of wire may damage the circuit.
Specially formulated 20GA Nickel/Chrome wire is recommended. Spring on wire holder should be fully compressed