Operating manual part II
II-14 © 2013 Dürkopp Adler AG
L C P Min Max Preset Unity Description
Machine run blockage
t 50 00 0 1 1 - Machine run blockage
0 = off;
1 = on
t 50 01 0 1 0 - The mode of operation from machine run blockage switch
0 = NC;
1 = NO
t 50 02 0 1 1 - Emergency shutdown of the motor or motor places
0 = Emergency shutdown;
1 = Direct positioning
Miscellaneous of the control
t 51 00 - - - - Showing software version
t 51 01 - - - - Showing control serial number
t 51 02 0 1 0 - Show the analog value (t 51 12) during sewing process.
0 = No;
1 = Yes
t 51 04 - - - - Showing machine class and –sub class
t 51 05 - - - - Showing hours of operation
t 51 06 - - - - Showing stitches of operation
t 51 07 - - - - Showing piece counter
t 51 10 0 4 - - Load of parameters
0 = Nothing;
1 = Sewing data from the dongle;
2 = Sewing data of the backup area;
3 = Seam ways from the Dongle
4 = Master reset
t 51 11 0 3 - - Store of parameters
0 = Nothing;
1 = Sewing data to the dongle;
2 = Sewing data to the backup area;
3 = Seam ways to the Dongle