(continued
Generator
is
not on level
Move generator to a level surface to
from page
surface.
prevent low oil shutdown from
19)
triggering.
Oil is low Add or replace oil.
Engine
Circuit breaker is off.
Set the circuit breaker to the "ON"
position.
runs but
If you are using an extension cord,
there is no
Bad connecting wires/cables.
try a different one.
electrical
Bad electrical device
output
Try connecting a different device.
connected to generator.
Generator
Generator is overloaded
Try connecting fewer electrical loads
runs but to the generator.
does not
Shorten one
of
the connected
Try disconnecting any faulty
or
support all
devices.
short-circuited electrical loads.
electrical
devices
Air cleaner is dirty. Clean or replace air cleaner.
connected.
GENERATOR ASSEMBLY AND MOUNTING
Generator is supplied with a wheel kit. If you want to install the wheel kit on your unit, please
follow the instructions below. If you will not
be
using the wheel kit, skip this section.
1.
Place the bottom of the generator cradle on a flat, even surface. Temporarily place
unit on blocks to ease assembly.
2.
Secure the support leg to the cradle with cap screws (M8 x 16) and lock nuts (M8)
(see
figure 22
).
3.
Secure the axle to the cradle with cap screws (M8 x 16) and lock nuts (M8) (see figure
23).
4. Slide a wheel (with the inflation valve facing out) and a flat washer over the axle, then
secure the wheel with a retaining pin (see
figure 24,Figure
25,
Figure 26).
5.
Position the handles on the cradle and attach with plastic flat washer, cap screws (M8
X 16) and lock nuts(M8)(
Figure 27,Figure 28).
6.
Check that all fasteners are tight and tires are inflated between 15-40 PSI.
Figure
22
Figure
23
23
Figure 24