36
Installation Manual
WATER QUALITY
All Dux water heating appliances are constructed from high quality materials and
components and all are certified for compliance with relevant parts of Australian and New
Zealand gas, electrical and water standards.
Whilst Dux water heaters are warranted against defects, the warranty is conditional upon
correct installation and use, in accordance with detailed instructions provided with the
heater. In the case of the water supplied to the heater, it is important that the water quality
be of acceptable standard.
The water quality limits/parameters listed in water quality table are considered acceptable
and generally, Australian and New Zealand suburban water supplies fall within these
limits/parameters.
In areas of Australia and New Zealand where water may be supplied, either fully or partly,
from bores, artesian wells or similar, one or more of the important limits may well be
exceeded and the heater could, therefore, be at risk of failure.
Where uncertainty exists concerning water quality, intending appliance users should seek
a water analysis from the water supplying authority and in cases where it is established
that the water supply does not meet the quality requirements of the water quality table,
the Dux warranty would not apply.
WATER QUALITY TABLE
Maximum levels
pH Saturation Total Chlorides Sodium Iron
Index(LSI) Hardness
(langelier)
6.5-9 +0.4 to 200mg/l 250mg/l 180mg/l 1mg/l
Minus 1.0
@65C
37
Installation Manual
Multi-System
G
(1 1/4"-2")
(1 1/4"-2")
Unit 6
Unit 2
Unit 1
System Controller
Gas Pipe
Cold Water Supply
Pipe
Remote Controller
Hot Water
Supply
Pipe
A. Installation without a recirculation system (Standard System)
Insulate or apply heating materials to both the cold water supply piping and the hot water supply
piping to prevent freezing during cold weather and to prevent heat loss through the piping.
SBB80RX_P001-P044_E_tonb.indd 36 2017/01/27 8:14:01