VENT-FREE
BLUE FLAME
GAS WALL HEATER
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: This appliance is equipped for
(natural or propane) gas. Field conversion is not
permitted.
- Do not store or use gasoline or other ammable vapors and Iiquids in vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the
gas supplier.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 8 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
C US
C US
ANS Z21.11.2-2016
Gas Fired Room Heaters
Volume II - Unvented Room Heaters
IMBF4 - 2019-01-15
MODEL #
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-447-4768,
8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
email us at customerservice@ghpgroupinc.com.
Propane
BF10PTDG-4/PMDG-4
BF20PTDG-4/PMDG-4
BF30PTDG-4/PMDG-4
Natural Gas
BF10NTDG-4/NMDG-4
BF20NTDG-4/NMDG-4
BF30NTDG-4/NMDG-4

Questions and Answers

  • A
    Anthony AllenSep 4, 2025
    What causes a high yellow flame during burner combustion in Dyna-Glo BF10PTDG-4?
    • V
      vargasrickySep 4, 2025
      A high yellow flame during burner combustion in your Dyna-Glo heater indicates that there is not enough air. Check the burner for dirt and debris. Also, the gas regulator may be defective, so consider replacing it.
  • J
    Jason MillerSep 18, 2025
    Why is there white powder residue forming within the burner box or on adjacent walls or furniture when using my Dyna-Glo BF10PTDG-4 Heater?
    • C
      carterjeffreySep 18, 2025
      The white powder residue forming within the burner box or on adjacent surfaces when using your Dyna-Glo heater is caused by vapors from furniture polish, wax, carpet cleaners, etc., turning into white powder when heated. Turn off the heater when using these products.
  • K
    Kathleen FryeSep 16, 2025
    Why is there a slight smoke or odor during initial operation of my Dyna-Glo BF10PTDG-4?
    • W
      wallaceashleySep 16, 2025
      If you notice a slight smoke or odor during the initial operation of your Dyna-Glo heater, this is likely due to residues from the manufacturing process. This problem should stop after a few hours of operation.
  • T
    Tasha WrightSep 14, 2025
    Why is my Dyna-Glo BF10PTDG-4 fan making a loud noise? (Select Models)
    • T
      Trevor MccarthySep 14, 2025
      If the fan on your Dyna-Glo heater (select models) is making a loud noise, the fan housing or blades may be dirty. Also, check if the fan rotation is blocked by wiring or other obstructions. If these are not the causes, the fan may be defective and need to be replaced.
  • V
    vanessamunozSep 13, 2025
    Why is my Dyna-Glo Heater fan not spinning? (Select Models)
    • G
      George ParksSep 13, 2025
      If the fan on your Dyna-Glo heater (select models) is not spinning, first verify that the fan is plugged in and set to "MAN" or "AUTO". If it's set to "AUTO", allow 5-10 minutes for the fan to engage. If these steps don't work, the fan motor may be bad and require replacement.
  • C
    Catherine LaneSep 12, 2025
    Why is my Dyna-Glo BF10PTDG-4 Heater producing a clicking/ticking noise just after the burner is lit or shut off?
    • M
      Mark RobinsonSep 12, 2025
      A clicking or ticking noise from your Dyna-Glo heater just after the burner is lit or shut off is typically due to metal expanding while heating or contracting while cooling, which is common in most heaters. If the noise is excessive, contact a qualified service technician.
  • T
    Travis WilliamsSep 9, 2025
    Why is my Dyna-Glo BF10PTDG-4 Heater producing a whistling noise when the burner is lit?
    • D
      dlyonsSep 9, 2025
      If your Dyna-Glo heater is producing a whistling noise when the burner is lit, try turning the control knob to the low (1) position and let it warm up for a minute, especially if you turned it to the high (5) position when the burner was cold. Air in the gas line can also cause this; operate the burner until the air is removed from the line. Blocked air passageways on the heater can also be a factor. Also, a dirty or partially clogged burner orifice might be the cause.
  • J
    Jacqueline RobinsonSep 7, 2025
    What to do if Dyna-Glo BF10PTDG-4 Heater produces unwanted odors?
    • D
      Daniel GarrettSep 7, 2025
      If your Dyna-Glo heater produces unwanted odors, ventilate the room and stop using odor-causing products while the heater is running, as the heater might be burning vapors from paint, hair spray, or glues. Also, check for gas leaks and correct them. Lastly, if you have a propane/LP model, check and refill the fuel supply tank if it's low.
  • C
    carrveronicaSep 5, 2025
    What causes burner backfiring during combustion in Dyna-Glo Heater?
    • M
      Michael MuellerSep 5, 2025
      Burner backfiring during combustion in your Dyna-Glo heater can be caused by a clogged or damaged burner orifice. Alternatively, the burner could be damaged. In some cases, a damaged gas regulator may also be the cause, so consider replacing it.
  • B
    bcoxAug 20, 2025
    What to do if my Dyna-Glo BF10PTDG-4 shuts off after a few minutes?
    • C
      Carla RossAug 21, 2025
      If your Dyna-Glo heater shuts off after running a few minutes, there are several potential causes. First, ensure the gas supply is turned on and the equipment shutoff valve is open. Also, make sure the control knob is fully pressed in while pressing the ignitor, and that the control knob is in the PILOT position. If there is air in the gas lines from installation, continue holding down the control knob and repeat the igniting operation until the air is removed. In case of a depleted propane supply, contact your local propane company. Finally, the ODS/pilot may be clogged, in which case you should clean the ODS/pilot assembly.