EasyManua.ls Logo

Dyna-Glo BFSS10LPT-4P - User Manual

Dyna-Glo BFSS10LPT-4P
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VENT-FREE
BLUE FLAME
GAS WALL HEATER
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: This appliance is equipped for
(natural or propane) gas. Field conversion is not
permitted.
- Do not store or use gasoline or other ammable vapors and Iiquids in vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the
gas supplier.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 8 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
C US
C US
ANS Z21.11.2-2016
Gas Fired Room Heaters
Volume II - Unvented Room Heaters
IMBFSS4 - 2019-01-15
MODEL #
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
email us at customerservice@ghpgroupinc.com.
Propane
BFSS10LPT-4P
BFSS20LPT-4P
BFSS30LPT-4P
Natural Gas
BFSS10NGT-4N
BFSS20NGT-4N
BFSS30NGT-4N

Questions and Answers

  • B
    Bobby WatkinsAug 18, 2025
    How to fix a Dyna-Glo BFSS10LPT-4P Heater when there is no spark at the pilot?
    • S
      Stephen PrinceAug 18, 2025
      If there's no spark when you press the ignitor on your Dyna-Glo heater, several things could be the cause. It could be due to the ignitor electrode being positioned wrong or broken, in which case you should replace the ODS. Another reason could be that the ignitor electrode isn't connected to the ignitor cable, or the cable is damaged, so you should replace the ignitor cable. If the ignitor cable is pinched or wet, free it from any obstruction and keep it dry. A bad ignitor, ignition module, or battery can also prevent a spark, so replace the ignitor, ignition module, or the battery.
  • S
    Stacey FrancisAug 20, 2025
    Why does the pilot light go out when I release the control knob on my Dyna-Glo BFSS10LPT-4P?
    • N
      Nicole SchroederAug 20, 2025
      If the pilot light on your Dyna-Glo heater goes out when you release the control knob, make sure you are pressing the control knob fully and holding it in long enough (30-60 seconds) after the pilot lights. Also, ensure the equipment shutoff valve is fully open. A loose thermocouple connection can also cause this issue; hand tighten it until snug, then tighten an additional ¼ turn. If the thermocouple is damaged, it should be replaced. It could also be the result of the inlet gas pressure being too high, in which case you should contact your gas supplier to check and adjust the inlet pressure.
  • Y
    ymillerAug 22, 2025
    What to do if my Dyna-Glo Heater shuts off after a few minutes?
    • Z
      zmonroeAug 23, 2025
      If your Dyna-Glo heater shuts off after running for a few minutes, first check that the gas supply is turned on and the equipment shutoff valve is open. Ensure the control knob is fully pressed in while pressing the ignitor. If there's air in the gas lines, continue holding down the control knob and repeat the igniting operation until the air is removed. The ODS/pilot might be clogged, so clean the ODS/pilot, and ensure the control knob is in the PILOT position. Finally, check if the propane supply is depleted and contact your local propane/LP gas company if needed.
  • S
    Shannon GallegosAug 26, 2025
    Why won't the burner light on my Dyna-Glo BFSS10LPT-4P after the pilot is lit?
    • G
      Greg KrauseAug 26, 2025
      If the burner on your Dyna-Glo heater doesn't light after the pilot is lit, make sure the thermostat setting is not too low by turning the thermostat knob to a higher setting. Another cause could be a clogged burner orifice, so you should clean the burner orifice. It may also be that the inlet gas pressure is too low, in which case you should contact your gas supplier.
  • R
    Raymond LopezAug 28, 2025
    Why does my Dyna-Glo Heater shut off while in use?
    • M
      Matthew WilsonAug 28, 2025
      If your Dyna-Glo heater shuts off while in use, and the ODS operates, it could be due to insufficient fresh air. Open a window and/or door for ventilation. Low line pressure can also cause this, so contact your local gas supplier. Additionally, the ODS/pilot might be partially clogged, so try cleaning it.
  • J
    Jennifer ReevesAug 30, 2025
    Why is there a delayed ignition of the burner on my Dyna-Glo Heater?
    • S
      Shelby McconnellAug 30, 2025
      A delayed ignition of the burner(s) on your Dyna-Glo heater could be due to low manifold pressure, in which case you should contact your gas supplier. Another possible cause is a clogged burner orifice, so you should clean the burner.
  • A
    Anna MortonSep 2, 2025
    Why does my Dyna-Glo BFSS10LPT-4P Heater produce unwanted odors?
    • A
      Amy RamirezSep 2, 2025
      Your Dyna-Glo heater might produce unwanted odors if it's burning vapors from paint, hair spray, glues, or other products. Ventilate the room and stop using odor-causing products while the heater is running. It could also be due to a gas leak, so locate and correct any leaks. Another possibility is a low fuel supply, so refill the supply tank if you are using Propane /LP models.
  • E
    Elizabeth WolfSep 4, 2025
    Why is there a high yellow flame during combustion in my Dyna-Glo BFSS10LPT-4P?
    • C
      cassidy74Sep 4, 2025
      A high yellow flame during burner combustion in your Dyna-Glo heater indicates that there's not enough air. Check the burner for dirt and debris, and if found, clean the burner. It could also be that the gas regulator is defective, so you should replace the gas regulator.
  • R
    Russell JacksonSep 7, 2025
    What causes burner backfiring during combustion in my Dyna-Glo Heater?
    • K
      Kelsey RoblesSep 7, 2025
      Burner backfiring during combustion in your Dyna-Glo heater can be caused by a clogged or damaged burner orifice, so you should clean the burner orifice. Alternatively, the burner itself may be damaged. Another cause could be a damaged gas regulator, so replace the gas regulator.
  • K
    Karen BrownSep 9, 2025
    Why do I smell gas during combustion with my Dyna-Glo BFSS10LPT-4P?
    • M
      Margaret WolfeSep 9, 2025
      If you smell gas during combustion with your Dyna-Glo heater, it could be due to foreign matter between the control valve and burner; take apart the gas tubing and remove any foreign matter. It could also be due to a gas leak, so locate and correct all leaks.

Dyna-Glo BFSS10LPT-4P Specifications

General IconGeneral
ModelBFSS10LPT-4P
BrandDyna-Glo
Heating Area300 sq. ft.
Weight20 lbs
Ventilation RequiredYes
Heater TypePortable
Fuel TypePropane
BTU Output10, 000 BTU
Safety FeaturesOxygen Depletion Sensor (ODS)