USER’S MANUAL AND OPERATING INSTRUCTIONS
C US
PROPANE CONSTRUCTION HEATER
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.
CONSUMER: Retain this manual for future reference.
Printed in China IMLPFDG - LCL
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
RMC-FA40DGD/DGD-01 (40,000 BTU/HR, FORCED - AIR)
RMC-FA60DGD/DGD-01 (30,000/60,000 BTU/HR, FORCED - AIR)
RMC-FA125DGD/LPFA125DGD/DGD-01 (70,000/125,000 BTU/HR, FORCED - AIR)
RMC-FA150DGD/DGD-01 (120,000/150,000 BTU/HR, FORCED - AIR)
RMC-FA40/DGP/DGP-01 (40,000 BTU/HR, FORCED - AIR)
RMC-FA60/DGP/DGP-01 (30,000/60,000 BTU/HR, FORCED - AIR)
RMC-FA125/DGP/DGP-01 (70,000/125,000 BTU/HR, FORCED - AIR)
LPFA125H/LPFA125H-01
RMC-FA150/DGP/DGP-01 (120,000/150,000 BTU/HR, FORCED - AIR)
ANS Z83.7-2017 CSA 2.14-2017
Contruction Heater
Adequate ventilation must be provided.
FA60 BTU Series FA125 BTU Series
FA40 BTU Series

Questions and Answers

  • J
    James CarterAug 12, 2025
    Why does my Dyna-Glo FA40 BTU keep quitting while running?
    • M
      Michelle HodgeAug 12, 2025
      If your Dyna-Glo Gas Heater quits while running, it might be due to a high internal temperature triggering the limit switch. Ensure the heater's output isn't blocked by moving it away from obstructions. Another potential cause is a damaged control valve, which would need replacing. Also, dust or debris buildup inside the heater can cause it to stop; clean the inside of the heater to resolve this.
  • J
    Janet YoungAug 22, 2025
    What to do if my Dyna-Glo FA40 BTU Gas Heater will not fire?
    • H
      Heather JonesAug 22, 2025
      If your Dyna-Glo Gas Heater won't fire, start by inspecting the ignitor wire and re-attaching or tightening it if it's loose. Next, check the spark gap and set it according to the specifications. If the issue persists, the electrode might be bad and need replacement.
  • W
    walkerlisaAug 31, 2025
    How to fix a Dyna-Glo FA40 BTU when the fan does not turn on?
    • J
      John GomezAug 31, 2025
      If your Dyna-Glo Gas Heater fan isn't turning when connected, first check the power supply to the outlet. If there is power, ensure the fan blades aren't hitting the heater housing or obstructed. Bent fan blades can also prevent rotation; straighten them to match the others. If none of these issues are present, the fan motor may be defective and require replacement.

Dyna-Glo FA40 BTU Series Specifications

General IconGeneral
BrandDyna-Glo
ModelFA40 BTU Series
CategoryGas Heater
LanguageEnglish

Related product manuals