GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.
CONSUMER: Retain this manual for future reference.
Printed in China IMLPFWH - HDW
USER’S MANUAL AND OPERATING INSTRUCTIONS
PROPANE
CONSTRUCTION HEATER
LPFA40WH (40,000 BTU/HR, FORCED - AIR)
LPFA60WH (30,000/60,000 BTU/HR, FORCED - AIR)
LPFA125WH (70,000/125,000 BTU/HR, FORCED - AIR)
LPFA150WH (120,000/150,000 BTU/HR, FORCED - AIR)
MODELS:
C US
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
series
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com

Questions and Answers

  • K
    Kevin VelazquezAug 11, 2025
    Why does my Dyna-Glo LPFA40WH Gas Heater quit while running?
    • M
      michaelcookAug 12, 2025
      Your Dyna-Glo Gas Heater might be shutting off due to several reasons: * The internal temperature may be too high, causing the limit switch to activate. If the heater's output is blocked, move it away from any obstructions. * A damaged control valve could be the cause. Consider replacing the control valve. * Dust or debris buildup inside the heater can also lead to shutdowns. Clean the inside of the heater to resolve this.
  • A
    amy08Aug 20, 2025
    What to do if Dyna-Glo LPFA40WH will not fire?
    • L
      lmartinAug 21, 2025
      If your Dyna-Glo Gas Heater won't ignite, consider these potential causes: * **No spark at the ignitor:** Inspect the ignitor wire, reattach or tighten it if loose. Check the spark module and replace if needed. * **Improper spark gap:** Set the spark gap according to the specifications. * **Bad electrode:** Replace the spark plug.
  • D
    David WrightAug 30, 2025
    How to fix a Dyna-Glo LPFA40WH Gas Heater fan that does not turn on?
    • R
      Rhonda OnealAug 30, 2025
      If the fan on your Dyna-Glo Gas Heater isn't working, here are a few things to check: 1. **No electric power:** Verify that the heater is receiving power from the outlet. 2. **Fan blade obstruction:** Ensure the housing isn't damaged and that nothing is blocking the fan blades. 3. **Bent fan blades:** Straighten any bent fan blades to match the others. 4. **Defective fan motor:** Replace the motor.