EasyManua.ls Logo

Dyna-Glo BF10DTDG-4 - User Manual

Dyna-Glo BF10DTDG-4
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
VENT-FREE
BLUE FLAME
GAS WALL HEATER
MODEL #BF10DTDG-4
BF20DTDG-4
BF30DTDG-4
GBF30DTDG-4
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: This appliance is equipped for
Natural and Propane gas. Field conversion is
not permitted.
- Do not store or use gasoline or other ammable vapors and Iiquids in vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the
gas supplier.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 8 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with propane or natural gas.
This appliance is equipped with a simple means to switch between propane and natural gas.
Field conversion by any other means including the use of a kit is not permitted.
C US
WARNING: Do not attempt to access or change
the setting of the fuel selection means.
Access to and adjustment of the fuel selection means
must only be performed by a qualied service person
when connecting this appliance to a specied fuel
supply at the time of installation.
Change of the selector setting to other than the fuel type
specied at the time of installation could damage this
appliance and render it inoperable.
The installer shall replace the access cover before
completing the installation and operating this appliance.
C US
ANS Z21.11.2-2016
Gas Fired Room Heaters
Volume II - Unvented Room Heaters
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
email us at customerservice@ghpgroupinc.com.
IMDFBFG4 - 2019-03-25
Patent Pending Dual
Fuel System

Questions and Answers

  • J
    Jose JohnsonAug 21, 2025
    What to do if Dyna-Glo BF10DTDG-4 Gas Heater pilot light goes out when releasing knob?
    • N
      Nathan WoodsAug 21, 2025
      If your Dyna-Glo Gas Heater's ODS/pilot lights, but the flame goes out when you release the control knob: * Ensure the control knob is fully pressed in. * After the ODS/pilot lights, keep the control knob pressed in for 30-60 seconds. * Make sure the equipment shutoff valve is fully open. * Check the thermocouple connection and hand tighten it until it is snug, then tighten an additional ¼ turn. * If the thermocouple is damaged, replace it. * If the control valve is damaged, contact customer service. * Ensure the gas setting is correct.
  • C
    Candace MahoneyAug 25, 2025
    Why won't the burner light on my Dyna-Glo BF10DTDG-4 Gas Heater after the pilot is lit?
    • T
      Tracy HernandezAug 25, 2025
      If the burner(s) on your Dyna-Glo Gas Heater don't light after the ODS/pilot is lit: * Make sure the thermostat setting is not too low. Turn the thermostat knob to a higher setting. * Check if the burner orifice is clogged. If so, clean the burner orifice or contact customer service. * The burner orifice diameter may be too small, in which case you should contact customer service. * The inlet gas pressure may be too low, so contact your gas supplier.
  • M
    Melissa CastroAug 26, 2025
    Why does my Dyna-Glo Gas Heater keep shutting off?
    • B
      Brandon HicksAug 27, 2025
      If your Dyna-Glo Gas Heater shuts off during use (ODS operates): * There may not be enough fresh air available. Open a window and/or door for ventilation. * There may be low line pressure. Contact your local gas supplier. * The ODS/pilot may be partially clogged. Clean the ODS/pilot.
  • C
    chouseAug 28, 2025
    Why does my Dyna-Glo BF10DTDG-4 smell like gas when off?
    • S
      Susan LeAug 28, 2025
      If you notice a gas odor when your Dyna-Glo Gas Heater control knob is in the OFF position, it could be due to: * A gas leak. Locate and correct all leaks. * A defective control valve. In this case, contact customer service.
  • J
    James JonesAug 30, 2025
    Why is the flame on my Dyna-Glo BF10DTDG-4 Gas Heater yellow?
    • K
      Kristi KaneAug 30, 2025
      If your Dyna-Glo Gas Heater has a high yellow flame during burner combustion, here's what could be happening: * There may not be enough air. Check the burner for dirt and debris, and clean it if necessary. * The gas regulator could be defective. Replace the gas regulator. * The wrong gas type may be selected. Refer to the Gas Selection section of the manual.
  • A
    Amber WilliamsSep 1, 2025
    Why does my Dyna-Glo Gas Heater smell like gas when it's running?
    • D
      Denise CarpenterSep 1, 2025
      If your Dyna-Glo Gas Heater has a gas odor during combustion: * There may be foreign matter between the control valve and burner. Take apart the gas tubing and remove any foreign matter. * There might be a gas leak. Locate and correct all leaks.
  • A
    Ashley MurraySep 3, 2025
    Why is there a delay when my Dyna-Glo BF10DTDG-4 burner ignites?
    • D
      Dana RowlandSep 3, 2025
      If you're experiencing delayed ignition of the burner(s) on your Dyna-Glo Gas Heater: * The manifold pressure may be too low. Contact your gas supplier. * The burner orifice may be clogged. Clean the burner or contact customer service.
  • A
    atkinsonloriSep 6, 2025
    Why is my Dyna-Glo Gas Heater burner backfiring?
    • J
      Jeffrey WoodSep 6, 2025
      If your Dyna-Glo Gas Heater burner is backfiring during combustion: * The burner orifice may be clogged or damaged. Clean the burner orifice or contact customer service. * The burner may be damaged. Contact your dealer or customer service. * The gas regulator may be damaged. Replace the gas regulator.
  • C
    Christina YorkSep 8, 2025
    How to fix a Dyna-Glo Gas Heater with no spark?
    • C
      Cindy BakerSep 8, 2025
      If the ignitor module on your Dyna-Glo Gas Heater is pressed and there is no spark at the ODS/pilot: * The ignitor electrode may be positioned wrong; replace the ODS. * The ignitor electrode may be broken; replace the ODS. * The ignitor electrode may not be connected to the ignitor cable; replace the ignitor cable. * The ignitor cable may be pinched or wet; free the ignitor cable if pinched and keep it dry. * The ignitor cable may be damaged; replace the ignitor cable. * The ignitor module or ignition module may be bad; replace the ignitor module or ignition module.
  • T
    Thomas SimmonsSep 10, 2025
    Why is my Dyna-Glo BF10DTDG-4 Gas Heater whistling?
    • G
      Glen SandersSep 10, 2025
      If your Dyna-Glo Gas Heater produces a whistling noise when the burner is lit: * You may have turned the control knob to the high position when the burner was cold. Turn the control knob to the low position and let it warm up for a minute. * There may be air in the gas line. Operate the burner until the air is removed from the line and have the gas line checked by your local propane company. * The air passageways on the heater may be blocked. Observe minimum installation clearances. * The burner orifice may be dirty or partially clogged. Clean the burner or contact customer service.