29CA 262/362/512 M262EN2
Fig. 49 Cab
1. Fresh air filter
2. Screw (x2)
Fresh air filter – Replacement
Use a stepladder to reach the filter (1).
As an alternative the filter can be reached
via the cab window on the right side.
Loosen the two screws (2) at the rear of the cab roof.
Take down the whole holder and remove the filter
insert.
Replace with a new filter.
It may be necessary to replace the filter more often if
the machine is used in a dusty environment.
1
EVERY 1000 HOURS OF OPERATION (Every six months)