5. Certain pipe and liquid characteristics may cause Signal
Strength to rise to greater than 100. The problem with
operating a TFXL with very high Signal Strength is that the
signals may saturate the input amplifiers and cause erratic
readings. To decrease the Signal Strength, move one
transducer a small distance radially around the pipe, as shown
in Figure 2.4.
PART 2 - TRANSDUCER INSTALLATION
Figure 2.3
Transducer Position
(Top view of pipe)
Figure 2.4
High Signal Strength Condition