Rev. 01/11 - 2.17 - TFXL-X
D010-2102-010 Mounting Rail Installation
1. The D010-2102-010 transducer mounting track is used for
pipes that have outside diameters between 2 and 10 inches (50
-250 mm). If the pipe is outside of that range then select a
standard V-Mount or W-Mount mounting method.
2. Install the single mounting rail on the side of the pipe with the
stainless steel bands provided. Do not mount it on the top or
bottom of the pipe. Orientation on vertical pipe is not critical.
Ensure that the track is parallel to the pipe and that all four
mounting feet are touching the pipe.
3. Slide the two transducer clamp brackets towards the center, 5
inch (125 mm) mark, on the mounting rail.
4. Place a single bead of couplant, approximately ½ inch (12 mm)
thick, on the flat face of the transducer. See Figure 2.2 on
page 2.9.
5. Place the first transducer in between the mounting rails near
the zero point on the mounting rail scale. Slide the transducer
clamp over the transducer. Adjust the clamp/transducer such
that the notch in the clamp aligns with zero on the scale. See
Figure 2.14.
6. Secure with the thumb screw. Ensure that the screw rests in
the counter bore on the top of the transducer. (Excessive
pressure is not required. Apply just enough pressure so that the
couplant fills the gap between the pipe and transducer.)
7. Place the second transducer in between the mounting rails
near the dimension derived in the Transducer Spacing section.
Read the dimension on the mounting rail scale. Slide the
transducer clamp over the transducer and secure with the
thumb screw.
PART 2 - TRANSDUCER INSTALLATION
Figure 2.14
D010-2102-010 Mounting Track Installation
Mounting Rail
Installation