Step 8: Install feet protection fenders.
4.4 Items to be checked before finishing installation.
Noise with rated load ≤75dB(A);
Grounding resistance: not bigger than 4Ω;
Mechanical locks are robust and synchronized when running with rated load ;
If the control button works as “hold to run”?
If limit switches work well?
If grounding wire is connected?
If rise and lower smoothly?
If there is no abnormal noise during running with rated load?
If there is no oil leakage when running with rated load?
If all bolts, nuts or circlips is well secured?
If max lifting height is 1000mm?
If Safety advices, name plate and logos are clear?