EW-5010A OPERATION MANUAL
23
8
The gel box is full. Please
reset after clearing.
The number of colloid particles can be modified
according to the size of the colloid particles.
9
The gel particle or trigger
induction is abnormal. Please
check!
Check whether there is rubber particles or the trigger
sensor light is off. If it is off, it may be that the spring
does not reset the wire top block.
10
Trigger sensor is normally
open, please check!
The trigger sensor light goes out. If it goes out, it may
be that the spring does not reset the wire top block.
11
No terminal is detected, and
the terminal of the vibrating
plate guide groove is
confirmed.
Check if the terminal feed rail is stuck.
12
The origin of the backward
cylinder is abnormal. Please
check!
X10 is red when the machine is normally stopped,
check for wire disconnection or the terminal rubber
seat plug is loosened.
13
The origin of the lead cylinder
is abnormal. Please check!
X12 is red when the machine is stopped normally.
Check the wire is broken or the terminal rubber seat
plug is loosened.
14
Peeling length motor returns
to zero alarm!
No touch is detected, check whether the touch is
normal, the wire is broken, or the terminal rubber seat
plug is loosened.
Caution!!! When the above alarms need to be handled inside the
machine, you must turn off the automatic mode or emergency stop. If
necessary, cut off the air source to avoid injury.