14
Remotes or
wireless
keypad not
working.
- Re program remotes by pressing the RF
learn button until a blue light next to it
comes on. Press the remote ONCE and it
should flicker. Now wait until the light goes
off and try again.
- You can program in several remotes or
devices at a time however all signals need
to be sent before the blue light goes off
again.
- Push the button fairly solid and hold it in for
a whole second. The blue light should
flicker.
- When programming remotes press the top
left button ONLY. The rest of the buttons
will program themselves in with it.
- If the blue light is on continuously without
pressing the RF learn button it means the
receiver is faulty and needs to be replaced.
- The blue light will still flash when a remote
that has not been programmed in is used. It
will however not activate.
- Reset the keypad. Do this by flicking off the
front cover with a small screw driver. Undo
the 2 nuts, turn over and repeat until left
with the control board on the casing. Undo
the 3 screws in the corner. Turn over the
circuit board and there is a button there.
Hold it until you hear a beep. Try keypad
again and reassemble.
RF Learn button on
control board
Lights on the
board but
arm(s) not
moving.
- Check that the battery is 24V+
- Make sure your connections aren’t loose.
- The power input is feeding in 24V+
- The gate is free from any obstructions.
- The arm is locked into place (A good way to
test this is if you can move the gate freely,
then it won’t work via the motors).
- Ensure a systems learn has been done from
start to finish.
- You have correctly wired the wires from the
rams to the control box.
The gate
Power sources
Arm wires.
Blue light
stays on
permanently
- Ensure you have waited the full 10 seconds.
- Try depowering and repowering the board.
- If it still keeps glowing please call or email
EasyGate. Receiver may need replacement.