Place the stripped and cleaned fiber across the v-groove (see picture below).
You can see how it is performed in our VIDEO to be found at:
https://www.dropbox.com/sh/t1bwwrk0i9str6a/AAAKnje_Mvc-_SeXVUH1v0Jva?dl=0
Having placed the fiber in the v-groove enter the “Menu” again and step with “down-arrow”
to CALIBRATE.
Select it (large button) and the splicer will perform a calibration.
If AUTO MODE is selected the calibration will start automatically when the lid is closed and
the splicer sees the fiber going all the way.
This is seen on the display as the splicer will ignite the spark and shine through the fiber
with various strength.
The operation is finished after some 10 seconds and the display will show “OK” if the
Calibration was done properly.
If not, the display will show the text: “CALIBRATE AGAIN”.
* The splicer will adjust to the performed calibration with small steps
at every splice but when changing environment this calibration will
be needed (as the Calibration function compensate with many steps
up/down if necessary).
TURN OVEN ON
Use this function to manually run the oven program. Normally, when a
splice is done the oven program will be executed automatically (see
above “Oven operation” page 6).
But under some circumstances You might want to operate the oven
manually.
If so, place a fiber with a shrink-tube (sleeve) in the oven compartment
and press the OVEN-button. The oven will start and run for as long as
the oven time is set (factory preset is 45 sec.)
Change time under “SETUP” and “Oven” below.